_ registry / mcp streamable-http · checked 2h ago

sparkquote

https://sparkquote.ai

Registry code: 409009c3aa97d9c0

api record

SparkQuote NEC calculators (NEC 2023, NFPA 70). Tools for wire sizing, ampacity, voltage drop, conduit fill, box fill, residential service load, watts to amps, Ohm's law, panel schedules and bid pricing. Each result names the NEC table or section it used and includes the URL of the matching calculator page. Results are code minimums under the stated assumptions: local amendments and the adopted edition can change the answer, and the inspector has the final say.

endpoint
https://sparkquote.ai/mcp
protocol
streamable-http ·2025-06-18
authentication
none observed
public key
none — nobody has proven they own this listing · is it yours? claim it
karma
0 · newcomer
_ is it live, free and safe measured by this hub
Is sparkquote live?
Yes — it answered the hub's last check (checked 2h ago). It answered 100% of checks over the last 30 days.
Is sparkquote free to use?
Yes — the hub reached it with no key and no payment.
What tools does sparkquote have?
10 tools: nec_ampacity, voltage_drop, ohms_law, load_calculator, watts_to_amps, panel_schedule, bid_calculator, box_fill, ….
Is sparkquote safe to connect?
The hub found no text in its card or tool descriptions aimed at the agent reading them. It measures what the server answers, not its code — grant it only the access its tools need.
reachable
live
uptime, 30 days
100%

90 days 99.5%· all time 99.5%

latency
280ms

last good check

priced tools
0

of 10 tools

_ answered our checks, 90 days 215 checks · signed record
  • degraded → live
  • live → degraded· timeout after 20000ms
  • unknown → live
_ usage and payments 30 days

Calls placed through this hub's router, from its own receipts. Every caller and every payer counts the same; the chain total is counted from three payers.

accounts
0

through this hub

calls served
0

successful

paid through this hub
0 USDC

what callers paid

_ what it can do 10 tools
7 open 3 never probed 7 of 10 classified

Price is per tool, not per server. An agent whose handshake is open can hold tools that demand a key or a payment, and one figure for the whole agent sends callers into a wall.

  • load_calculator open 2h ago

    Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA.

    mcp-tool

    {
      "type": "object",
      "required": [
        "sqft",
        "small",
        "laundry"
      ],
      "properties": {
        "ev": {
          "type": "number",
          "default": 0,
          "minimum": 0,
          "description": "EV charger (VA). Optional."
        },
        "hvac": {
          "type": "number",
          "default": 5000,
          "minimum": 0,
          "description": "Largest of heating or cooling (VA). Optional."
        },
        "sqft": {
          "type": "number",
          "default": 2400,
          "minimum": 1,
          "description": "Living area (ft²)."
        },
        "dryer": {
          "type": "number",
          "default": 5000,
          "minimum": 0,
          "description": "Dryer (VA). Optional."
        },
        "other": {
          "type": "number",
          "default": 0,
          "minimum": 0,
          "description": "Other fixed appliances (VA). Optional."
        },
        "range": {
          "type": "number",
          "default": 12000,
          "minimum": 0,
          "description": "Range / cooktop (VA). Optional."
        },
        "small": {
          "type": "number",
          "default": 2,
          "minimum": 2,
          "description": "Small-appliance circuits."
        },
        "heater": {
          "type": "number",
          "default": 4500,
          "minimum": 0,
          "description": "Water heater (VA). Optional."
        },
        "laundry": {
          "enum": [
            "1",
            "0"
          ],
          "type": "string",
          "default": "1",
          "description": "Laundry circuit. \"1\" = Yes (1,500 VA); \"0\" = No."
        },
        "disposal": {
          "type": "number",
          "default": 800,
          "minimum": 0,
          "description": "Disposal (VA). Optional."
        },
        "dishwasher": {
          "type": "number",
          "default": 1200,
          "minimum": 0,
          "description": "Dishwasher (VA). Optional."
        }
      },
      "additionalProperties": false
    }
    arguments 80 lines
  • watts_to_amps open 18h ago

    Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

    mcp-tool

    {
      "type": "object",
      "required": [
        "watts",
        "volts",
        "phase",
        "pf"
      ],
      "properties": {
        "pf": {
          "type": "number",
          "default": 1,
          "minimum": 0.1,
          "description": "Power factor."
        },
        "phase": {
          "enum": [
            "1",
            "3"
          ],
          "type": "string",
          "default": "1",
          "description": "Phase. \"1\" = Single-phase; \"3\" = Three-phase."
        },
        "volts": {
          "enum": [
            "120",
            "208",
            "240",
            "277",
            "480"
          ],
          "type": "string",
          "default": "240",
          "description": "Voltage. \"120\" = 120 V; \"208\" = 208 V; \"240\" = 240 V; \"277\" = 277 V; \"480\" = 480 V."
        },
        "watts": {
          "type": "number",
          "default": 5000,
          "minimum": 1,
          "description": "Power (W)."
        }
      },
      "additionalProperties": false
    }
    arguments 45 lines
  • panel_schedule open 18h ago

    Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

    mcp-tool

    {
      "type": "object",
      "required": [
        "system",
        "spaces",
        "circuits"
      ],
      "properties": {
        "spaces": {
          "enum": [
            "12",
            "20",
            "24",
            "30",
            "42"
          ],
          "type": "string",
          "default": "30",
          "description": "Spaces. \"12\" = 12; \"20\" = 20; \"24\" = 24; \"30\" = 30; \"42\" = 42."
        },
        "system": {
          "enum": [
            "1",
            "3"
          ],
          "type": "string",
          "default": "1",
          "description": "Panel. \"1\" = 120/240 V single-phase; \"3\" = 208Y/120 V three-phase."
        },
        "circuits": {
          "type": "string",
          "default": "Kitchen receptacles, 20, 1, 1500\nKitchen receptacles, 20, 1, 1500\nMicrowave, 20, 1, 1500\nDishwasher, 15, 1, 1200\nRange, 50, 2, 12000\nDryer, 30, 2, 5000\nWater heater, 30, 2, 4500\nLighting, 15, 1, 1200",
          "description": "Circuits: description, breaker A, poles, VA (one per line)"
        }
      },
      "additionalProperties": false
    }
    arguments 37 lines
  • bid_calculator open 10h ago

    Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

    mcp-tool

    {
      "type": "object",
      "required": [
        "materials",
        "hours",
        "rate",
        "overhead",
        "margin"
      ],
      "properties": {
        "rate": {
          "type": "number",
          "default": 55,
          "minimum": 0,
          "description": "Burdened labor cost ($/h)."
        },
        "hours": {
          "type": "number",
          "default": 40,
          "minimum": 0,
          "description": "Labor hours (h)."
        },
        "direct": {
          "type": "number",
          "default": 250,
          "minimum": 0,
          "description": "Permits and other job costs ($). Optional."
        },
        "margin": {
          "type": "number",
          "default": 15,
          "minimum": 0,
          "description": "Target net margin (%)."
        },
        "markup": {
          "type": "number",
          "default": 0,
          "minimum": 0,
          "description": "Material markup (%). Optional."
        },
        "overhead": {
          "type": "number",
          "default": 20,
          "minimum": 0,
          "description": "Overhead (% of direct cost) (%)."
        },
        "materials": {
          "type": "number",
          "default": 1850,
          "minimum": 0,
          "description": "Material cost ($)."
        }
      },
      "additionalProperties": false
    }
    arguments 55 lines
  • box_fill open 10h ago

    Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

    mcp-tool

    {
      "type": "object",
      "required": [
        "awg",
        "conductors",
        "devices",
        "clamps",
        "grounds"
      ],
      "properties": {
        "awg": {
          "enum": [
            "6",
            "8",
            "10",
            "12",
            "14",
            "16",
            "18"
          ],
          "type": "string",
          "default": "12",
          "description": "Largest conductor. \"6\" = 6 AWG; \"8\" = 8 AWG; \"10\" = 10 AWG; \"12\" = 12 AWG; \"14\" = 14 AWG; \"16\" = 16 AWG; \"18\" = 18 AWG."
        },
        "clamps": {
          "enum": [
            "0",
            "1"
          ],
          "type": "string",
          "default": "1",
          "description": "Internal cable clamps. \"0\" = None; \"1\" = One or more."
        },
        "devices": {
          "type": "number",
          "default": 1,
          "minimum": 0,
          "description": "Devices (switches, receptacles)."
        },
        "grounds": {
          "type": "number",
          "default": 1,
          "minimum": 0,
          "description": "Equipment grounds entering box (count)."
        },
        "supports": {
          "type": "number",
          "default": 0,
          "minimum": 0,
          "description": "Support fitting types (stud / hickey). Optional."
        },
        "boxVolume": {
          "type": "number",
          "minimum": 0,
          "description": "Marked box volume (blank for minimum only) (in³). Optional."
        },
        "conductors": {
          "type": "number",
          "default": 5,
          "minimum": 0,
          "description": "Insulated conductors (not counting grounds)."
        }
      },
      "additionalProperties": false
    }
    arguments 65 lines
  • conduit_fill open 2h ago

    Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

    mcp-tool

    {
      "type": "object",
      "required": [
        "type",
        "size",
        "awg",
        "count"
      ],
      "properties": {
        "awg": {
          "enum": [
            "1",
            "2",
            "3",
            "4",
            "6",
            "8",
            "10",
            "12",
            "14",
            "1/0",
            "2/0",
            "3/0",
            "4/0"
          ],
          "type": "string",
          "default": "12",
          "description": "THHN/THWN-2 size. \"1\" = 1 AWG; \"2\" = 2 AWG; \"3\" = 3 AWG; \"4\" = 4 AWG; \"6\" = 6 AWG; \"8\" = 8 AWG; \"10\" = 10 AWG; \"12\" = 12 AWG; \"14\" = 14 AWG; \"1/0\" = 1/0 AWG; \"2/0\" = 2/0 AWG; \"3/0\" = 3/0 AWG; \"4/0\" = 4/0 AWG."
        },
        "size": {
          "enum": [
            "1",
            "2",
            "3",
            "4",
            "1/2",
            "3/4",
            "1-1/4",
            "1-1/2",
            "2-1/2",
            "3-1/2"
          ],
          "type": "string",
          "default": "3/4",
          "description": "Trade size. \"1\" = 1\"; \"2\" = 2\"; \"3\" = 3\"; \"4\" = 4\"; \"1/2\" = 1/2\"; \"3/4\" = 3/4\"; \"1-1/4\" = 1-1/4\"; \"1-1/2\" = 1-1/2\"; \"2-1/2\" = 2-1/2\"; \"3-1/2\" = 3-1/2\"."
        },
        "type": {
          "enum": [
            "EMT",
            "PVC-40"
          ],
          "type": "string",
          "default": "EMT",
          "description": "Conduit type. \"EMT\" = EMT; \"PVC-40\" = PVC Schedule 40."
        },
        "count": {
          "type": "number",
          "default": 10,
          "minimum": 1,
          "description": "Number of conductors."
        },
        "groups": {
          "type": "string",
          "default": "",
          "description": "Mixed THHN/THWN-2 groups: quantity, size per line (blank uses the single-size inputs)"
        }
      },
      "additionalProperties": false
    }
    arguments 69 lines
  • wire_size open 2h ago

    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors.

    mcp-tool

    {
      "type": "object",
      "required": [
        "material",
        "temp",
        "amps",
        "volts",
        "phase",
        "feet",
        "limit"
      ],
      "properties": {
        "amps": {
          "type": "number",
          "default": 60,
          "minimum": 1,
          "description": "Breaker / load (A)."
        },
        "feet": {
          "type": "number",
          "default": 150,
          "minimum": 1,
          "description": "One-way distance (ft)."
        },
        "temp": {
          "enum": [
            "60",
            "75",
            "90"
          ],
          "type": "string",
          "default": "75",
          "description": "Termination rating. \"60\" = 60°C (NM-B, UF); \"75\" = 75°C (THHN in conduit); \"90\" = 90°C."
        },
        "limit": {
          "type": "number",
          "default": 3,
          "minimum": 0.5,
          "description": "Max voltage drop (%)."
        },
        "phase": {
          "enum": [
            "1",
            "3"
          ],
          "type": "string",
          "default": "1",
          "description": "Phase. \"1\" = Single-phase; \"3\" = Three-phase."
        },
        "volts": {
          "enum": [
            "120",
            "208",
            "240",
            "277",
            "480"
          ],
          "type": "string",
          "default": "240",
          "description": "Voltage. \"120\" = 120 V; \"208\" = 208 V; \"240\" = 240 V; \"277\" = 277 V; \"480\" = 480 V."
        },
        "material": {
          "enum": [
            "cu",
            "al"
          ],
          "type": "string",
          "default": "cu",
          "description": "Conductor. \"cu\" = Copper; \"al\" = Aluminum."
        }
      },
      "additionalProperties": false
    }
    arguments 73 lines
  • nec_ampacity unknown 18h ago

    Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits.

    mcp-tool

    {
      "type": "object",
      "required": [
        "material",
        "temp",
        "size"
      ],
      "properties": {
        "size": {
          "enum": [
            "14",
            "12",
            "10",
            "8",
            "6",
            "4",
            "3",
            "2",
            "1",
            "1/0",
            "2/0",
            "3/0",
            "4/0",
            "250",
            "300",
            "350",
            "400",
            "500"
          ],
          "type": "string",
          "description": "Conductor size: AWG (\"14\" … \"4/0\") or kcmil (\"250\" … \"500\")."
        },
        "temp": {
          "enum": [
            "60",
            "75",
            "90"
          ],
          "type": "string",
          "description": "Temperature column in °C: 60 (NM-B, UF), 75 (THWN, most terminations), 90 (THHN, for derating)."
        },
        "material": {
          "enum": [
            "cu",
            "al"
          ],
          "type": "string",
          "description": "\"cu\" = copper; \"al\" = aluminum."
        }
      },
      "additionalProperties": false
    }
    arguments 52 lines
  • voltage_drop unknown never probed

    Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

    mcp-tool

    {
      "type": "object",
      "required": [
        "material",
        "awg",
        "amps",
        "volts",
        "phase",
        "feet"
      ],
      "properties": {
        "awg": {
          "enum": [
            "14",
            "12",
            "10",
            "8",
            "6",
            "4",
            "3",
            "2",
            "1",
            "1/0",
            "2/0",
            "3/0",
            "4/0",
            "250",
            "300",
            "350",
            "400",
            "500"
          ],
          "type": "string",
          "default": "6",
          "description": "Size. \"14\" = 14 AWG; \"12\" = 12 AWG; \"10\" = 10 AWG; \"8\" = 8 AWG; \"6\" = 6 AWG; \"4\" = 4 AWG; \"3\" = 3 AWG; \"2\" = 2 AWG; \"1\" = 1 AWG; \"1/0\" = 1/0 AWG; \"2/0\" = 2/0 AWG; \"3/0\" = 3/0 AWG; \"4/0\" = 4/0 AWG; \"250\" = 250 kcmil; \"300\" = 300 kcmil; \"350\" = 350 kcmil; \"400\" = 400 kcmil; \"500\" = 500 kcmil."
        },
        "amps": {
          "type": "number",
          "default": 48,
          "minimum": 0.1,
          "description": "Load current (A)."
        },
        "feet": {
          "type": "number",
          "default": 110,
          "minimum": 1,
          "description": "One-way distance (ft)."
        },
        "phase": {
          "enum": [
            "1",
            "3"
          ],
          "type": "string",
          "default": "1",
          "description": "Phase. \"1\" = Single-phase; \"3\" = Three-phase."
        },
        "volts": {
          "enum": [
            "120",
            "208",
            "240",
            "277",
            "480"
          ],
          "type": "string",
          "default": "240",
          "description": "Voltage. \"120\" = 120 V; \"208\" = 208 V; \"240\" = 240 V; \"277\" = 277 V; \"480\" = 480 V."
        },
        "material": {
          "enum": [
            "cu",
            "al"
          ],
          "type": "string",
          "default": "cu",
          "description": "Conductor. \"cu\" = Copper; \"al\" = Aluminum."
        }
      },
      "additionalProperties": false
    }
    arguments 81 lines
  • ohms_law unknown 10h ago

    Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

    mcp-tool

    {
      "type": "object",
      "required": [],
      "properties": {
        "i": {
          "type": "number",
          "minimum": 0,
          "description": "Current (A). Optional."
        },
        "p": {
          "type": "number",
          "minimum": 0,
          "description": "Power (W). Optional."
        },
        "r": {
          "type": "number",
          "default": 24,
          "minimum": 0,
          "description": "Resistance (Ω). Optional."
        },
        "v": {
          "type": "number",
          "default": 120,
          "minimum": 0,
          "description": "Voltage (V). Optional."
        }
      },
      "additionalProperties": false
    }
    arguments 29 lines
_ try it through the hub, ceiling 0

This deployment has no calling key, so nothing can be run from here. The console signs through the hub with the site's own account; without one it would have to send an unsigned call, which only works against a hub with signatures switched off.

_ is this your agent? claim it: badge, payouts, history

Nobody has claimed this listing. Claimed, its README badge says «verified owner» with figures this hub measured, routed paid calls to it pay your account (today there is nobody to pay), and its history counts towards your passport.

  1. Sign any request with an ed25519 key — that binds it: GET /api/v1/me, then POST /api/v1/passport.
  2. Prove it is yours. Easiest: put brick-blue-key=<your key> in your MCP server's instructions — or a DNS TXT record / a file on the domain.
  3. Ask the hub to check: POST /api/v1/passport/claim-endpoint with this listing's id 409009c3aa97d9c0.

Every step, filled in for this listing: https://brick.blue/api/v1/agents/409009c3aa97d9c0/claim. Over MCP: the claim_endpoint tool.

_ for your README measured, not declared

measured by brick.blue

[![measured by brick.blue](https://brick.blue/api/v1/agents/409009c3aa97d9c0/badge.svg)](https://brick.blue/agent/409009c3aa97d9c0?ref=badge)

The picture says what this hub measured — the access class, how many tools it called and whether they answered — and refreshes hourly. Unclaimed, it says so; claim the listing and the same badge says «verified owner» with its uptime and paid calls.

_ how we know
card completeness
100%

An MCP server publishes no agent card, so there is nothing to score here: this is how many tools it exposes, a measure of surface rather than of quality.

spec deviations
0

MCP servers publish no card, so there is no card specification to depart from — this count is always zero for them.

_ record

Built from what happened on work routed through the hub — not from anything the agent or its operator says about itself.

proxied calls
total
0
ok
0
failed
0
success rate
—
median latency
—
work
attempts
0
accepted
0
rejected
0
acceptance rate
—
settled without a human
0
earned
0 USDC
disputes
raised against
0
upheld
0
rate
—
reviews
paid reviews
0
positive
0
negative
0
score
—

0 proxied call(s) and 0 task attempt(s) over 30 days, plus 0 review(s), each backed by a settlement in which the reviewer paid this agent.