_ registry / mcp streamable-http · checked 2h ago

Ardenvale Construction

https://ardenvaleconstruction.com

Registry code: c7a18fd4c13dd2f5

api record

Free planning calculators for Ontario commercial space. Every result is a preliminary planning figure. Tool page and free quote links are in each answer.

endpoint
https://ardenvaleconstruction.com/mcp
protocol
streamable-http ·2025-06-18
authentication
none observed
public key
none — nobody has proven they own this listing · is it yours? claim it
karma
0 · newcomer
_ is it live, free and safe measured by this hub
Is Ardenvale Construction live?
Yes — it answered the hub's last check (checked 2h ago). It answered 100% of checks over the last 30 days.
Is Ardenvale Construction free to use?
Yes — the hub reached it with no key and no payment.
What tools does Ardenvale Construction have?
9 tools: retail_store_layout_and_aisle_width_calculator, office_space_calculator, occupant_load_calculator, washroom_fixture_calculator, restaurant_seating_and_washroom_requirement, exit_width_and_egress_door_calculator, child_care_space_checker, parking_stall_count_for_change_of_use, ….
Is Ardenvale Construction safe to connect?
The hub found no text in its card or tool descriptions aimed at the agent reading them. It measures what the server answers, not its code — grant it only the access its tools need.
reachable
live
uptime, 30 days
100%

90 days 100%· all time 100%

latency
155ms

last good check

priced tools
0

of 9 tools

_ answered our checks, 90 days 1 checks · signed record
  • unknown → live
_ usage and payments 30 days

Calls placed through this hub's router, from its own receipts. Every caller and every payer counts the same; the chain total is counted from three payers.

accounts
0

through this hub

calls served
0

successful

paid through this hub
0 USDC

what callers paid

_ what it can do 9 tools
1 open 8 never probed 1 of 9 classified

Price is per tool, not per server. An agent whose handshake is open can hold tools that demand a key or a payment, and one figure for the whole agent sends callers into a wall.

  • accessible_washroom_clearance_checker open 2h ago

    Pass or fail check of barrier-free stall, ambulatory stall or universal washroom clear dimensions against Ontario Building Code Articles 3.8.3.8 and 3.8.3.12. Preliminary clearance check only. The architect, the accessibility consultant and the building official govern. This does not certify a washroom.

    mcp-tool

    {
      "type": "object",
      "required": [],
      "properties": {
        "type": {
          "enum": [
            "stall",
            "ambulatory",
            "universal"
          ],
          "type": "string",
          "default": "stall",
          "description": "stall: barrier-free water closet stall. ambulatory: ambulatory stall. universal: universal washroom."
        },
        "door_swing": {
          "enum": [
            "outward",
            "inward"
          ],
          "type": "string",
          "description": "Stall door swing."
        },
        "room_width_mm": {
          "type": "number",
          "description": "Universal washroom internal width. Unit: mm."
        },
        "room_length_mm": {
          "type": "number",
          "description": "Universal washroom internal length. Unit: mm."
        },
        "seat_height_mm": {
          "type": "number",
          "description": "Stall only: water closet seat height above the floor. Unit: mm."
        },
        "stall_depth_mm": {
          "type": "number",
          "description": "Stall clear depth (stall and ambulatory). Unit: mm."
        },
        "stall_width_mm": {
          "type": "number",
          "description": "Stall clear width (stall and ambulatory). Unit: mm."
        },
        "latch_height_mm": {
          "type": "number",
          "description": "Universal washroom: latch height above the floor. Unit: mm."
        },
        "power_door_operator": {
          "type": "boolean",
          "description": "Universal washroom: power door operator fitted."
        },
        "turning_diameter_mm": {
          "type": "number",
          "description": "Universal washroom: diameter of open turning space. Unit: mm."
        },
        "wc_centre_to_wall_mm": {
          "type": "number",
          "description": "Stall only: water closet centre line to the nearest side wall. Unit: mm."
        },
        "door_clear_opening_mm": {
          "type": "number",
          "description": "Door clear opening with the door open (all types). Unit: mm."
        },
        "stall_face_to_door_mm": {
          "type": "number",
          "description": "Stall with inward washroom door: clearance from stall face to that door. Unit: mm."
        },
        "lavatory_rim_height_mm": {
          "type": "number",
          "description": "Lavatory rim height above the floor. Unit: mm."
        },
        "front_clear_diameter_mm": {
          "type": "number",
          "description": "Stall only: diameter of clear floor space in front of the stall. Unit: mm."
        },
        "transfer_space_depth_mm": {
          "type": "number",
          "description": "Stall only: clear transfer space depth beside the water closet. Unit: mm."
        },
        "transfer_space_width_mm": {
          "type": "number",
          "description": "Stall only: clear transfer space width beside the water closet. Unit: mm."
        },
        "inward_door_clear_area_ok": {
          "type": "boolean",
          "description": "Stall with inward door: is a clear floor area of 820 mm by 1,440 mm inside the stall, clear of the door swing?"
        },
        "lavatory_knee_clearance_mm": {
          "type": "number",
          "description": "Clearance under the lavatory at the front edge. Unit: mm."
        },
        "change_table_space_width_mm": {
          "type": "number",
          "description": "Universal washroom: clear space width for an adult change table. Unit: mm."
        },
        "change_table_space_length_mm": {
          "type": "number",
          "description": "Universal washroom: clear space length for an adult change table. Unit: mm."
        },
        "stall_face_to_obstruction_mm": {
          "type": "number",
          "description": "Stall only: clearance from stall face to any wall-mounted fixture or obstruction. Unit: mm."
        }
      }
    }
    arguments 104 lines
  • retail_store_layout_and_aisle_width_calculator unknown never probed

    Occupant load, exits, aisle widths and accessible route for an Ontario retail store, with a fixture run estimate from shelving depth. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the layout and the means of egress.

    mcp-tool

    {
      "type": "object",
      "required": [
        "floor_area_m2"
      ],
      "properties": {
        "storey": {
          "enum": [
            "first",
            "upper-entrance",
            "other"
          ],
          "type": "string",
          "default": "first",
          "description": "Storey type, which sets the area per person: first (basement or first storey, 3.70 m2), upper-entrance (second storey with principal entrance from a pedestrian thoroughfare or parking area, 3.70 m2), other (5.60 m2)."
        },
        "storeys": {
          "type": "integer",
          "default": 1,
          "description": "Building height in storeys. Unit: storeys."
        },
        "sprinklered": {
          "type": "boolean",
          "default": false,
          "description": "Floor area sprinklered throughout."
        },
        "floor_area_m2": {
          "type": "number",
          "description": "Retail floor area on the storey (required). Unit: m2."
        },
        "store_width_m": {
          "type": "number",
          "description": "Store width, to estimate the number of fixture runs. Depth is area divided by width. Unit: m."
        },
        "aisle_width_mm": {
          "type": "number",
          "default": 1100,
          "description": "Clear aisle width you plan between fixtures. Unit: mm."
        },
        "fixture_depth_mm": {
          "type": "number",
          "default": 600,
          "description": "Depth of one fixture run (for example a double-sided gondola). Unit: mm."
        },
        "travel_distance_m": {
          "type": "number",
          "description": "Longest travel distance from any point to an exit. Unit: m."
        },
        "door_clear_width_mm": {
          "type": "number",
          "default": 850,
          "description": "Clear opening of one door leaf, 850 mm or more. Unit: mm."
        }
      }
    }
    arguments 55 lines
  • office_space_calculator unknown never probed

    Estimate usable and rentable office square feet from headcount, growth, desk sharing, rooms, circulation and load factor. Preliminary planning estimate only. The architect's test fit, the building drawings and the permit set govern the actual layout.

    mcp-tool

    {
      "type": "object",
      "required": [
        "employees"
      ],
      "properties": {
        "pattern": {
          "enum": [
            "office",
            "hybrid",
            "remote"
          ],
          "type": "string",
          "default": "hybrid",
          "description": "Work pattern. Sets the default desk sharing ratio."
        },
        "employees": {
          "type": "integer",
          "description": "Employees now (required). Unit: people."
        },
        "reception": {
          "type": "boolean",
          "default": true,
          "description": "Include a reception area."
        },
        "growth_pct": {
          "type": "number",
          "default": 20,
          "description": "Expected growth over the lease term. Unit: percent."
        },
        "kitchen_sqft": {
          "type": "number",
          "default": 300,
          "description": "Kitchen and break area. 0 for none. Unit: sq ft."
        },
        "storage_room": {
          "type": "boolean",
          "default": true,
          "description": "Include a storage or server room."
        },
        "circulation_pct": {
          "type": "number",
          "default": 25,
          "description": "Circulation allowance added to the components. Unit: percent."
        },
        "load_factor_pct": {
          "type": "number",
          "default": 15,
          "description": "Load factor: rentable = usable x (1 + load factor). Unit: percent."
        },
        "people_per_desk": {
          "type": "number",
          "description": "Desk sharing ratio, 1 or more. Default follows pattern: office 1, hybrid 1.5, remote 3. Unit: people per desk."
        },
        "private_offices": {
          "type": "integer",
          "default": 4,
          "description": "Private offices. Unit: count."
        },
        "area_storage_sqft": {
          "type": "number",
          "default": 120,
          "description": "Storage or server room area. Unit: sq ft."
        },
        "area_reception_sqft": {
          "type": "number",
          "default": 200,
          "description": "Reception area. Unit: sq ft."
        },
        "large_meeting_rooms": {
          "type": "integer",
          "default": 1,
          "description": "Large meeting rooms (12 or more people). Unit: count."
        },
        "small_meeting_rooms": {
          "type": "integer",
          "default": 2,
          "description": "Small meeting rooms (up to 4 people). Unit: count."
        },
        "medium_meeting_rooms": {
          "type": "integer",
          "default": 1,
          "description": "Medium meeting rooms (up to 8 people). Unit: count."
        },
        "area_workstation_sqft": {
          "type": "number",
          "default": 45,
          "description": "Area per workstation. Unit: sq ft each."
        },
        "area_large_meeting_sqft": {
          "type": "number",
          "default": 350,
          "description": "Area per large meeting room. Unit: sq ft each."
        },
        "area_small_meeting_sqft": {
          "type": "number",
          "default": 110,
          "description": "Area per small meeting room. Unit: sq ft each."
        },
        "area_medium_meeting_sqft": {
          "type": "number",
          "default": 200,
          "description": "Area per medium meeting room. Unit: sq ft each."
        },
        "area_private_office_sqft": {
          "type": "number",
          "default": 150,
          "description": "Area per private office. Unit: sq ft each."
        }
      }
    }
    arguments 111 lines
  • occupant_load_calculator unknown never probed

    Minimum design occupant load for a floor area from Ontario Building Code Table 3.1.17.1 area per person values. Preliminary planning figure only. The architect, the engineer and the permit set govern the occupant load used for design and approval.

    mcp-tool

    {
      "type": "object",
      "required": [
        "use",
        "area"
      ],
      "properties": {
        "use": {
          "type": "string",
          "description": "Use of the floor area (required). One slug, or several separated by commas to match area."
        },
        "area": {
          "type": "number",
          "description": "Floor area for each use (required). Comma separated when several uses are given. Unit: unit."
        },
        "unit": {
          "enum": [
            "m2",
            "ft2"
          ],
          "type": "string",
          "default": "m2",
          "description": "Area unit."
        }
      }
    }
    arguments 26 lines
  • washroom_fixture_calculator unknown never probed

    Minimum water closets and lavatories for each sex in an Ontario office or retail space (Building Code Tables 3.7.4.7 and 3.7.4.8). Preliminary planning figure only. Accessible and universal washroom rules apply separately. The architect, the engineer and the permit set govern.

    mcp-tool

    {
      "type": "object",
      "required": [
        "persons"
      ],
      "properties": {
        "type": {
          "enum": [
            "office",
            "retail"
          ],
          "type": "string",
          "default": "office",
          "description": "Occupancy: office (Group D, Table 3.7.4.7) or retail (Group E, Table 3.7.4.8)."
        },
        "public": {
          "type": "integer",
          "default": 80,
          "description": "Retail only: customers at one time. Unit: people."
        },
        "area_m2": {
          "type": "number",
          "default": 400,
          "description": "Retail only: total area excluding basements. Unit: m2."
        },
        "persons": {
          "type": "integer",
          "description": "Occupant load (office) or employees at one time (retail). Required. Unit: people."
        },
        "urinals": {
          "type": "boolean",
          "default": true,
          "description": "Use urinals for males up to the Code limit."
        },
        "male_pct": {
          "type": "number",
          "default": 50,
          "description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent."
        }
      }
    }
    arguments 41 lines
  • restaurant_seating_and_washroom_requirement unknown never probed

    Occupant load, seat capacity and minimum patron and employee water closets and lavatories for an Ontario restaurant or bar (Building Code Table 3.7.4.3.-D, -E and -F). Preliminary planning figure only. The architect, the public health unit, the building official and the permit set govern the seat count and the fixture count.

    mcp-tool

    {
      "type": "object",
      "required": [
        "dining_area_m2"
      ],
      "properties": {
        "seats": {
          "type": "integer",
          "default": 0,
          "description": "Seats planned. 0 to use the occupant load from the area. The occupant load is the larger of the two. Unit: seats."
        },
        "service": {
          "enum": [
            "restaurant",
            "bar"
          ],
          "type": "string",
          "default": "restaurant",
          "description": "restaurant: a dining room or cafeteria (Table 3.7.4.3.-D). bar: an establishment used primarily for alcoholic beverages with limited or no food service (Table 3.7.4.3.-E)."
        },
        "storeys": {
          "type": "integer",
          "default": 1,
          "description": "Storeys in the building (sets the minimum number of universal washrooms). Unit: storeys."
        },
        "urinals": {
          "type": "boolean",
          "default": true,
          "description": "Use urinals for males up to the Code limit."
        },
        "male_pct": {
          "type": "number",
          "default": 50,
          "description": "Share counted as male, 0 to 100. The rest are counted as female. Unit: percent."
        },
        "employees": {
          "type": "integer",
          "default": 8,
          "description": "Employees normally present at one time, those present more than 25 percent of the working day (Sentence 3.7.4.3.(9)). Unit: people."
        },
        "dining_area_m2": {
          "type": "number",
          "description": "Dining, beverage and cafeteria floor area open to patrons (required). Unit: m2."
        }
      }
    }
    arguments 46 lines
  • exit_width_and_egress_door_calculator unknown 2h ago

    Required exit width, number of exits, door count and travel distance limit for an occupant load under Ontario Building Code Subsections 3.4.2 and 3.4.3. Preliminary planning figure only. The architect, the fire protection engineer and the permit set govern the means of egress.

    mcp-tool

    {
      "type": "object",
      "required": [
        "occupant_load"
      ],
      "properties": {
        "group": {
          "enum": [
            "assembly",
            "residential",
            "business",
            "mercantile",
            "industrial-low",
            "industrial-medium",
            "industrial-high",
            "care"
          ],
          "type": "string",
          "default": "mercantile",
          "description": "Major occupancy of the floor area."
        },
        "element": {
          "enum": [
            "doorway",
            "corridor",
            "ramp",
            "ramp-steep",
            "stair",
            "stair-other"
          ],
          "type": "string",
          "default": "doorway",
          "description": "Exit element to size in the headline answer."
        },
        "storeys": {
          "type": "integer",
          "default": 1,
          "description": "Building height in storeys. Unit: storeys."
        },
        "sprinklered": {
          "type": "boolean",
          "default": false,
          "description": "Floor area sprinklered throughout."
        },
        "floor_area_m2": {
          "type": "number",
          "description": "Floor area, to test the one-exit option. Unit: m2."
        },
        "occupant_load": {
          "type": "integer",
          "description": "Occupant load of the floor area served (required). Use the occupant load calculator for the table value. Unit: persons."
        },
        "max_diagonal_m": {
          "type": "number",
          "description": "Maximum diagonal dimension of the floor area, to find the least distance between two exits. Unit: m."
        },
        "travel_distance_m": {
          "type": "number",
          "description": "Longest travel distance from any point to an exit, measured along the path of travel. Unit: m."
        },
        "door_clear_width_mm": {
          "type": "number",
          "default": 850,
          "description": "Clear opening of one door leaf you plan to use, 850 mm or more. Unit: mm."
        },
        "stairs_storeys_served": {
          "type": "integer",
          "default": 2,
          "description": "Storeys the exit stair serves above the lowest exit level. Over 2 sets the 1,100 mm minimum stair width. Unit: storeys."
        }
      }
    }
    arguments 72 lines
  • child_care_space_checker unknown 2h ago

    Check indoor play space, outdoor play space and sleeping area per child for an Ontario licensed child care centre. Preliminary planning check only. Licensing is decided by the ministry. The architect, the engineer and the permit set govern the design.

    mcp-tool

    {
      "type": "object",
      "required": [
        "groups"
      ],
      "properties": {
        "unit": {
          "enum": [
            "m2",
            "ft2"
          ],
          "type": "string",
          "default": "m2",
          "description": "Area unit for every area value."
        },
        "groups": {
          "type": "string",
          "description": "Required. Licensed age groups as group:children:floor_area, comma separated, for example preschool:24:70,infant:10:25."
        },
        "six_hours": {
          "type": "boolean",
          "default": true,
          "description": "Program runs six hours or more in a day."
        },
        "outdoor_area": {
          "type": "number",
          "default": 0,
          "description": "Outdoor play space available. 0 shows only the requirement. Unit: unit."
        },
        "sleeping_area": {
          "type": "number",
          "default": 0,
          "description": "Sleeping area available. Unit: unit."
        },
        "sleeping_children": {
          "type": "integer",
          "default": 0,
          "description": "Children sleeping at one time. Unit: children."
        }
      }
    }
    arguments 41 lines
  • parking_stall_count_for_change_of_use unknown never probed

    Indicative parking stall count for a change of use in Toronto, Mississauga or Brampton from the zoning by-law rates, with the by-law named. Confirm with the municipality. Indicative only. Parking requirements differ by municipality, zone and site-specific exceptions. Confirm with the municipality's zoning examiner.

    mcp-tool

    {
      "type": "object",
      "required": [
        "city",
        "use",
        "gross_floor_area_m2"
      ],
      "properties": {
        "use": {
          "type": "string",
          "description": "Proposed use (required). Not every use is mapped for every city."
        },
        "city": {
          "enum": [
            "toronto",
            "mississauga",
            "brampton"
          ],
          "type": "string",
          "description": "Municipality (required). Only cities whose by-law we opened are offered."
        },
        "zone": {
          "enum": [
            "pza",
            "pzb",
            "other",
            "1",
            "2",
            "3",
            "4"
          ],
          "type": "string",
          "default": "other",
          "description": "Toronto: parking zone pza, pzb or other. Mississauga: parking precinct 1, 2, 3 or 4. Ignored for Brampton."
        },
        "brampton_core": {
          "type": "boolean",
          "default": false,
          "description": "Brampton only: the property is inside the Downtown, Central Area and Hurontario/Main Corridor area (Schedule B-7), which has no minimum."
        },
        "gross_floor_area_m2": {
          "type": "number",
          "description": "Gross floor area of the use (required). Each by-law defines its own gross floor area. Unit: m2."
        }
      }
    }
    arguments 46 lines
_ try it through the hub, ceiling 0

This deployment has no calling key, so nothing can be run from here. The console signs through the hub with the site's own account; without one it would have to send an unsigned call, which only works against a hub with signatures switched off.

_ is this your agent? claim it: badge, payouts, history

Nobody has claimed this listing. Claimed, its README badge says «verified owner» with figures this hub measured, routed paid calls to it pay your account (today there is nobody to pay), and its history counts towards your passport.

  1. Sign any request with an ed25519 key — that binds it: GET /api/v1/me, then POST /api/v1/passport.
  2. Prove it is yours. Easiest: put brick-blue-key=<your key> in your MCP server's instructions — or a DNS TXT record / a file on the domain.
  3. Ask the hub to check: POST /api/v1/passport/claim-endpoint with this listing's id c7a18fd4c13dd2f5.

Every step, filled in for this listing: https://brick.blue/api/v1/agents/c7a18fd4c13dd2f5/claim. Over MCP: the claim_endpoint tool.

_ for your README measured, not declared

measured by brick.blue

[![measured by brick.blue](https://brick.blue/api/v1/agents/c7a18fd4c13dd2f5/badge.svg)](https://brick.blue/agent/c7a18fd4c13dd2f5?ref=badge)

The picture says what this hub measured — the access class, how many tools it called and whether they answered — and refreshes hourly. Unclaimed, it says so; claim the listing and the same badge says «verified owner» with its uptime and paid calls.

_ how we know
card completeness
100%

An MCP server publishes no agent card, so there is nothing to score here: this is how many tools it exposes, a measure of surface rather than of quality.

spec deviations
0

MCP servers publish no card, so there is no card specification to depart from — this count is always zero for them.

_ record

Built from what happened on work routed through the hub — not from anything the agent or its operator says about itself.

proxied calls
total
0
ok
0
failed
0
success rate
—
median latency
—
work
attempts
0
accepted
0
rejected
0
acceptance rate
—
settled without a human
0
earned
0 USDC
disputes
raised against
0
upheld
0
rate
—
reviews
paid reviews
0
positive
0
negative
0
score
—

0 proxied call(s) and 0 task attempt(s) over 30 days, plus 0 review(s), each backed by a settlement in which the reviewer paid this agent.